Specificaties
The latest C1000 Opaque Coolant launched by Thermaltake is used as anti-corrosion protection fluid and heat-transfer medium for PC water-cooling. Made in Germany, the C1000 Opaque coolant is virtually odorless, non-flammable, and high performance liquid, offering superb protection for copper, nickel, brass, and aluminum. Choose from seven vivid colors: red, green, blue, orange, yellow, white, and purple to brighten up any build with Thermaltake.
“Tt LCS Certified” is the hallmark that ensures first-class performance from the best features and fitment. A certification exclusive to Thermaltake, it sets the benchmark for all true LCS chassis and is applied only to products that meet our stringent design standards for delivering what hardcore enthusiasts demand. The Tt LCS certification is a way for Thermaltake to designate to all power users the chassis which have been tested for best compatibility with extreme liquid cooling configurations.
Note:
1.The coolant color may change over time.
2.The precipitations at the bottom of the bottle are considered normal.
Thermaltake recommends the following steps to be taken before using the Pacific series radiators and water blocks
- To ensure a clean loop, flush and rinse your radiators and water blocks with distilled water prior to use.
- Do not use tap water or distilled water as your coolant, it may harm your loop and reduce performance.
- It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while protecting the entire liquid loop from corrosion.
- Before storing your water cooling components, please clean, rinse and dry. This will ensure a longer lifespan for your components.
Thermaltake recommends the following steps to be taken after completing your water loop setup
- It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while preventing the entire cooling system – copper, brass, nickel, aluminum, and steel – from corrosion.
- Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
- DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
- Fill the reservoir to the top as it will prevent air from going into the pump
- If necessary tilt the system slightly from side to side to bleed the air out of the loop.
- Place some paper towels under fittings and joining points to test for leaks.
- Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop
- Before starting, flush out your system correctly to prevent any coolant or unwanted particles sticking to your tubes, radiators and other cooling components.
- Coolant might fade over time.
Specificaties
P/N | CL-W114-OS00BL-A CL-W114-OS00BU-A CL-W114-OS00GR-A CL-W114-OS00OR-A CL-W114-OS00PL-A CL-W114-OS00RE-A CL-W114-OS00WT-A CL-W114-OS00YE-A |
Color | Blue,Red,White,Green,Orange,Yellow,Purple,Black |
Capacity | 1000 ml |
Hazardous component | Ethanediol Value < 20% CAS 170-21-1 EG 203-473-3 Index 603-027-00-1 Certificate Xn R-Phrase 22 S-Phrase 2, 24/25,46 |
* Specifications are subject to change without notice.
* The product picture(s) is only for your reference, it may differ from the actual product.
Specificaties
The latest C1000 Opaque Coolant launched by Thermaltake is used as anti-corrosion protection fluid and heat-transfer medium for PC water-cooling. Made in Germany, the C1000 Opaque coolant is virtually odorless, non-flammable, and high performance liquid, offering superb protection for copper, nickel, brass, and aluminum. Choose from seven vivid colors: red, green, blue, orange, yellow, white, and purple to brighten up any build with Thermaltake.
“Tt LCS Certified” is the hallmark that ensures first-class performance from the best features and fitment. A certification exclusive to Thermaltake, it sets the benchmark for all true LCS chassis and is applied only to products that meet our stringent design standards for delivering what hardcore enthusiasts demand. The Tt LCS certification is a way for Thermaltake to designate to all power users the chassis which have been tested for best compatibility with extreme liquid cooling configurations.
Note:
1.The coolant color may change over time.
2.The precipitations at the bottom of the bottle are considered normal.
Thermaltake recommends the following steps to be taken before using the Pacific series radiators and water blocks
- To ensure a clean loop, flush and rinse your radiators and water blocks with distilled water prior to use.
- Do not use tap water or distilled water as your coolant, it may harm your loop and reduce performance.
- It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while protecting the entire liquid loop from corrosion.
- Before storing your water cooling components, please clean, rinse and dry. This will ensure a longer lifespan for your components.
Thermaltake recommends the following steps to be taken after completing your water loop setup
- It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while preventing the entire cooling system – copper, brass, nickel, aluminum, and steel – from corrosion.
- Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
- DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
- Fill the reservoir to the top as it will prevent air from going into the pump
- If necessary tilt the system slightly from side to side to bleed the air out of the loop.
- Place some paper towels under fittings and joining points to test for leaks.
- Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop
- Before starting, flush out your system correctly to prevent any coolant or unwanted particles sticking to your tubes, radiators and other cooling components.
- Coolant might fade over time.
Specificaties
P/N | CL-W114-OS00BL-A CL-W114-OS00BU-A CL-W114-OS00GR-A CL-W114-OS00OR-A CL-W114-OS00PL-A CL-W114-OS00RE-A CL-W114-OS00WT-A CL-W114-OS00YE-A |
Color | Blue,Red,White,Green,Orange,Yellow,Purple,Black |
Capacity | 1000 ml |
Hazardous component | Ethanediol Value < 20% CAS 170-21-1 EG 203-473-3 Index 603-027-00-1 Certificate Xn R-Phrase 22 S-Phrase 2, 24/25,46 |
* Specifications are subject to change without notice.
* The product picture(s) is only for your reference, it may differ from the actual product.